Development of GATE Monte Carlo Code for Simulation and Dosimetry of New I-125 Seeds in Eye Plaque Brachytherapy
P Taherparvar, Z Fardi - Nuclear Medicine and Molecular Imaging, 2021 - Springer
… seeds (such as 125 I, 103 Pd, and 131 Cs) have been … plaque containing IsoAid (IrSeed)
brachytherapy source was … -125 and IsoAid Advantage brachytherapy source models …
brachytherapy source was … -125 and IsoAid Advantage brachytherapy source models …
Determination of absorbed dose of Palladium-103 radiation sources in prostate brachytherapy using the Monte Carlo method
… The brachytherapy simulation in this study used the Monte Carlo method with the … Monte
Carlo Dosimetric Characterization of the IsoAid ADVANTAGE 103Pd Brachytherapy Source…
Carlo Dosimetric Characterization of the IsoAid ADVANTAGE 103Pd Brachytherapy Source…
Calculation of Absorbed Dose of 103Pd and 131Cs Sources in Prostate Cancer Brachytherapy Simulation Using Monte Carlo N-Particle 6 (MCNP-6) Software
MR Munggara, N Handayani, F Arianto - Engineering Headway, 2024 - Trans Tech Publ
… Figure 1 is a geometry seed 103Pd ADVANTAGE™ model, which refers to the geometry
model belonging to IsoAID LLC. The outside diameter of the capsule is 0.8 mm, with a length of …
model belonging to IsoAID LLC. The outside diameter of the capsule is 0.8 mm, with a length of …
[PDF][PDF] A Monte Carlo investigation of the dose distribution for new I-125 low dose rate brachytherapy source in water and in different media
Z Fardi, P Taherparvar - Polish Journal of Medical Physics and …, 2019 - sciendo.com
… The main advantages of brachytherapy technique are to eliminate … dosimetric characteristics
of InterSource125 Iodine … the dosimetric parameters of this brachytherapy source in the …
of InterSource125 Iodine … the dosimetric parameters of this brachytherapy source in the …
… Carlo study of the relationship between skin dose and optically stimulated luminescence dosimeter dose in Pd-103 permanent breast seed implant brachytherapy
S Nich, C Kirkby, JE Villarreal-Barajas - Brachytherapy, 2019 - Elsevier
… Monte Carlo simulations were performed in a simple breast phantom using the EGSnrc user
code egs_brachy. Realistic models of the IsoAid Advantage Pd-103 brachytherapy source …
code egs_brachy. Realistic models of the IsoAid Advantage Pd-103 brachytherapy source …
Comparison between dose distribution from 103Pd, 131Cs, and 125I plaques in a real human eye model with different tumor size
P Taherparvar, Z Fardi - Applied Radiation and Isotopes, 2022 - Elsevier
… The aim of this study is using the GATE 8.2 Monte Carlo code to … model for ophthalmic
brachytherapy dosimetry with different … IsoAid Advantage 125 I (model IAI-125) brachytherapy …
brachytherapy dosimetry with different … IsoAid Advantage 125 I (model IAI-125) brachytherapy …
Combining Monte Carlo simulations and detector measurements for a novel quality assurance system of assembled brachytherapy eye plaques.
SD Möehle - 2020 - open.library.ubc.ca
… of an IsoAid ADVANTAGE Pd-103 source with dimensions … used in the Monte Carlo simulation
of 103Pd brachytherapy seeds … measurements and Monte Carlo derived dosimetry, in the …
of 103Pd brachytherapy seeds … measurements and Monte Carlo derived dosimetry, in the …
Investigation of the dosimetric parameters of 125I BEBIG IsoSeed® I25. S06 source: GATE 8.2 Monte Carlo code
L Ait-Mlouk, M Khalis, H Asnaoui, H Ouabi… - Applied Radiation and …, 2022 - Elsevier
… The importance of this technique is due to its benefits like the … ) brachytherapy is essentially
done with 125 I, 103 Pd and … dosimetric characterization of some brachytherapy sources …
done with 125 I, 103 Pd and … dosimetric characterization of some brachytherapy sources …
Validation of the TOPAS Monte Carlo toolkit for LDR brachytherapy simulations
A Poher, F Berumen, Y Ma, J Perl, L Beaulieu - Physica Medica, 2023 - Elsevier
… at 5 cm (except for the 103 Pd sources, which was 2% at 5 cm), as it … As a result, a more
refined analysis is necessary, as seen in … The scaling of MC results to compare with the dosimetry …
refined analysis is necessary, as seen in … The scaling of MC results to compare with the dosimetry …
Monte Carlo-based optimization of glioma capsule design for enhanced brachytherapy
D Li, Y Liang, G Yao, Z Guan, H Zhao, N Zhang… - Applied Radiation and …, 2023 - Elsevier
… into the establishment of spatial dosimetric parameters for the dual-… source factor on the
absorbed dose of the water phantom was considered for the simulation analysis of brachytherapy…
absorbed dose of the water phantom was considered for the simulation analysis of brachytherapy…